Vista de pagina 0
Cool
Warm Time
Mode/Prog
Blower
Jets 2
Light
Jets 1
F2
TL
F1
PL
ML700 User Guide
EL/GL Series - Mach 3
Note regarding EL and GL systems: Mach 3 EL and GL systems function
identically, but conform to different International requirements. This
user guide will refer to EL systems for the sake of simplicity, but the
information given applies to both EL and GL products.
YXcYfX$`ejkild\ekj%Zfd
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - EL/GL Series - Mach 3

Cool Warm Time Mode/Prog BlowerJets 2LightJets 1F2 TL F1 PL ML700 User Guide EL/GL Series - Mach 3Note regarding EL and GL systems: Mach 3 EL and G

Pagina 2

Page 8GFCI ProtectionYour spa may be equipped with a GFCI Protection feature. If your spa does have this feature enabled, the GFCI Trip Test must occu

Pagina 3 - Initial Start-up

Page 9Jets 3, Jets 4 (optional on some systems)Press the “Jets 3” button once to turn pump 3 on or off, and to shift between low and high speeds if

Pagina 4

P/N 40520-99_A 12/09/2005Warning! Shock Hazard! No User Serviceable Parts.Do not attempt service of this control system. Contact your dealer or serv

Pagina 6

EL/GL SERIES (Mach 3) CONTROL WITH ML700 PANELThe ML700 panel can be used with the EL8000, EL5000, EL2000 and EL1000 systems. This user guide lists al

Pagina 7 - Editing User Preferences

Temp Set (80°F - 104°F / 26.0°C - 40.0°C)The last measured temperature is constantly displayed on the LCD.Note that the last measured spa temperature

Pagina 8 - Action Required

Jets 2 (optional on some systems)Press the “Jets 2” button once to turn pump 2 on or off, and to shift between low and high speeds if it is a two-spee

Pagina 9

Light Some systems are equipped with both a spa light and a fiber optic light; however, only one can be accessed by this panel. (Larger panels may be

Pagina 10 - GFCI Trip Test Procedure

Page 5Displaying Information About Your SpaThere are several pieces of information about your spa that can be called up from the panel, but are only n

Pagina 11

Diagnostic MessagesMessage MeaningNo message on display.Power has been cut off to the spa.“Overheat” - The spa has shut down. On some systems, an alar

Pagina 12 - Warning! GFCI Protection

Diagnostic Messages (continued)Message MeaningTemperature unknown.Temperature not current in Economy or Sleep mode.Standby Mode has been activated by